Updated on 12th December, by Martin Astley. When it comes to choosing a boiler in the UK, boiler code l2, The Ideal boiler is one of the popular brands that customers choose. Providing central heating to your homes for over a hundred years Ideal Boiler has developed recognition as one of the most reliable boiler manufacturers.

If your boiler is displaying Ideal fault code L2 then, to put it simply, your flame has gone out. This is a serious issue which you need to resolve as soon as possible if you want hot water in your home. Follow our guide below to learn more about the Ideal fault code L2. Resolving an issue with your boiler can be a daunting prospect. We have complied this guide to help you resolve the issues you may find with Ideal fault code L2. If you are seeing the Ideal fault code L2 then your boiler has lost its flame during operation. When this happens, your boiler will lockout as a safety precaution and thus resulted in flame loss.

Boiler code l2

This article describes what the external factors are and how an end user can resolve them and restart the boiler. Replacing gas cylinders It is not uncommon for a boiler to stop working after replacing a gas cylinder due to a lack of gas if the reserve cylinder on an automatic change over system has shut off or a single cylinder installation has emptied. Ignite all four burner rings on the cooker in the kitchen, open a hot water tap and leave the rings on for a few minutes. With the hob rings and the hot water tap running, reset the boiler please refer to the reset procedure on the final page of this article. This may take several attempts before the boiler re-sets. Please do not re-set the boiler more than 5 times in a 15 minute period as this will lock your boiler out and you will need to restart the process from the beginning. The boiler should then restart and ignite. Through the process of igniting the burner rings, this should remove the air within the gas pipe and the boiler can return to working normally. Gas stenching agent LPG which is supplied to a home produces a recognisable smell if it leaks. LPG in its natural form does not smell.

The information provided in this article has been collected boiler code l2 various sources. An indication of this occurring is when a gurgling noise is produced from the boiler and the condensate trap becomes discoloured and black.

.

An Ideal L2 fault code means your boiler has locked out because of flame failure. This can happen for many reasons. I have been repairing boilers full-time for over a decade and an L2 fault on an Ideal Logic boiler is quite a common boiler fix. The most likely cause of an L2 boiler fault is the boiler has been locked out due to low gas pressure or not getting any gas. Another cause of an L2 fault could be a blocked or frozen condensate pipe. An L2 boiler fault code could also mean that a part in the boiler is broken and needs to be replaced, but most of the time in my experience it is a gas supply issue. To fix the L2 fault on a boiler the first thing I would check is that the gas is turned on at the gas meters emergency control valve ECV.

Boiler code l2

Boilers show fault codes to give a repair engineer an indication of the problem. One of the most common Ideal boiler fault codes, the L2 fault code may relate to a gas supply issue or a problem that requires the boiler to be taken apart. The flame sensor on your Ideal Logic boiler could be to blame for the L2 on your boiler. On some occasions, the L2 fault code could have been caused by a disabled gas valve. The gas valve regulates the flow of gas into your boiler. It opens whenever you turn on your heating or hot water, and closes when you turn them off. Since the gas valve comprises moving parts, over time it can become stiff, or get stuck.

Synonyms for cursed

A safety measure that is implemented by the boiler due to blockages caused by sludge buildup and a frozen condensate pipe. If the problem persists, contact a Gas Safe Engineer. We always recommend that you have your heating system professionally serviced on a regular basis, ideally at least once a year as a preventative measure. Providing central heating to your homes for over a hundred years Ideal Boiler has developed recognition as one of the most reliable boiler manufacturers. Try repressurising your boiler; if this does not solve the issue, then contact your installer and let him rectify this issue. Skip to content. Nevertheless, there is no need to worry, as I will now outline the common error codes and their possible solutions, enabling you to address any issues that may arise effectively. April 8, This in turn also blocks the waste pipe and trap. View Our Policies. If you observe any of these error codes flashing on the display of your Ideal boiler, it indicates that your boiler needs assistance. Replace the outside sensor if it is faulty. Get your new boiler and save your heating bill yearly with new energy efficient boiler. Check that all radiator and boiler valves are open and reset the boiler. If you choose to ignore Ideal fault code L2 and you keep putting off having the issue resolved then you may end up having to go through the expensive process of replacing your boiler with a new, more efficient model.

Contact Us. The L2 Fault Code is a serious one.

If you choose to ignore Ideal fault code L2 and you keep putting off having the issue resolved then you may end up having to go through the expensive process of replacing your boiler with a new, more efficient model. Contact a qualified technician or certified engineer for further inspection. The best way to do this is by having your system serviced regularly to ensure any issues are resolved quickly and dealt with professionally by a Gas Safe engineer. Why is my Boiler Flashing F? Please do not re-set the boiler more than 5 times in a 15 minute period as this will lock your boiler out and you will need to restart the process from the beginning. Check the boiler pressure and refill if necessary, make sure it is at 1. Ensure the gas valve is open and there are no issues with the gas supply. Providing central heating to your homes for over a hundred years Ideal Boiler has developed recognition as one of the most reliable boiler manufacturers. Contact a qualified engineer if the issue persists. If the boiler fails to operate after the restart, contact a Gas Safe Engineer or the manufacturer if the boiler is under warranty. The Ideal boiler L2 fault means there is flame loss or some issue that can lead to a lockout. Through the process of igniting the burner rings, this should remove the air within the gas pipe and the boiler can return to working normally. This is a lesser-known boiler error code but if displayed, it means the pressure on your boiler has dropped and a water leak is stopping your system from functioning properly. This displays the water temperature that will be pumped from the boiler. Contact a certified professional if the voltage drops below VAC.